Selsoft logo Selsoft logo
Home About us Prices Order Contacts Guest book Russian version  

Digital Line Equipment Model MK-30TC10
 
MK30-TC: General View

       It is intended for E1/T1 transmission between digital automatic telephone exchange, from channels making multiplexer MK-30, IKM-6A/30 by our manufacture and the equipment of other manufacturers. The modern method of coding of a line signal – TC-PAM16 is applied in the equipment. The equipment MK-30TC10 provides E1/T1 transmission on one pair with regeneration section on 10 km in cable with S=1,2 mm2 and 6 km - in cable with S=0,5 mm2
      Equipment model MK-30TC10 can be applied for replacement of equipment model IÊÌ 15õ2 "Zone" at "digital" area as lengths of regeneration sections at them are identical. On sections where cable with S=1,2 mm2 is working now IKM-15 and IKM-30 with line code HDB3, MK-30TC provides an opportunity of E1/T1 transmission with reduction of quantity of regenerators and with simultaneous liberation of one pair. At 5 regenerator sites the total length of action of system is 75 km.
        So on cable with S=1,2 mm2 two Å1/T1 can be transmitted, and with the help of MK-30TP transcoder - four, that is 120 channels of voice-frequency E&M (connecting lines or direct subscribers of regional automatic telephone exchange

Cost of MK-30TC10 - 3 200 $ USD

Technical characteristics:
Line interface E1/T1
Recommendations ITU-I G.703, G.736
Rate of transmission 2048 kbps
Line code HDB3 or AMI
Input resistance 120 Om (symmetrical)
75 Om (asymmetrical)
Quantity of streams between half kits
2 pairs on 1024 kbps 1 pair on 2048 kbps
Attenuation of a signal between remote MK-30TC10
Attenuation no more 43 dB at frequency 250 kHz Attenuation no more 43 dB at frequency 350kHz
Quantity of pairs necessary for realization of connection between half kit
2 1
Power supply
Input voltage - 36 V … - 72 V
Power consumption no more 10 W
Dimensions
19'' * 4U


Examples of application


MK30-TC10

Networking of E1/T1 transmission at one pair in cables with S = 1,2 mm2 with length of regeneration section up to 10 km. It is used for E1/T1 transmission between two ATE or other equipment under protocol G.703.

 


site optimized for IE5.0 (or high)
Copyright Selsoft © 2004